CC-ST-1024

Q What is the external diameter of the insulation coating of the Control Unit cable (AWG23) and external signal cable (AWG25) for the CC-ST-1024 unit?

A

Core cable external diameter: AWG23 1.32mm, AWG25 0.88mm
The external cable diameter is 3.5mm for both cables.

QA No. 11-0080

Q What kind of extension cable should be used to connect the CC-ST-1024 unit with light units?

A

The main unit is equipped with a 1m cable for connecting to light units.
If you need extension cables, we also offer 1m, 2m, 3m, and 5m cables (model name: FCB-#).
For distances between the light units and Control Unit unit of greater than 5m, since a voltage drop will occur, we ask that you perform cable arrangement so that the total length is 5m or shorter.

QA No. 11-0079

Q Regarding the 24V input of the CC-ST-1024 unit, is there any noise immunity?

A

As it is a product that has a certified CE marking, noise immunity measures have been taken for the Control Unit lines, light unit lines, and external control lines.
(It is compliant with the CE marking requirements for the EMC Directive EN61000-6-2 standard.)
Moreover, in regards to external control, it is equipped with a photo coupler that further improves noise resistance.
The Control Unit line is equipped with a DC/DC converter, and it is designed to a specification that rectifies the voltage waveform.

QA No. 11-0078

Q For the CC-ST-1024 unit, is 24V output guaranteed even if connected to a 21.6V Control Unit?

A

The input voltage range for guaranteed operation is DC 24V+/-10% (21.6 to 26.4V).
If the input voltage is within the range shown above, the output will be 24V typ. (Product standard voltage: DC 23.45 to 24.65V).

QA No. 11-0077