Q Is it possible to perform ON/OFF switching by simultaneously triggering multiple CC-PJ-0707 units?

A

It is possible if inputs are connected in parallel.
This cannot be performed when connected in series.

QA No. 11-0138

Q Is the included cable for the CC-PJ-0707 a robot cable?

A

It is not a robot cable.
It is the same as a CCS standard extension cable.
The minimum bending radius is R 30mm.

QA No. 11-0137

Q How is the CC-PJ-0707 Control Unit turned ON/OFF?

A

Please turn the primary power source power ON.
When turning it off, please turn the primary power source power OFF.

QA No. 11-0135

Q If an error occurs while using the CC-PJ-0707, will it recover by itself?

A

It cannot recover on its own.
After the cause of the error is rectified, please restart the primary power source.

QA No. 11-0134

Q What is the trigger input method and response time after trigger signal input is sent for the CC-PJ-0707?

A

A waveform edge input method is used and it is a maximum of 50μs.

QA No. 11-0132

Q For the CC-PJ-0707, is it possible to perform adjustments with any tools other than the included flat-head screwdriver?

A

Although adjustment is possible, please ensure that excessive force is not applied.

QA No. 11-0130

Q Does the dimming for the CC-PJ-0707 exhibit linearity?

A

The dimming does exhibit linearity.

QA No. 11-0129

Q What precautions need to be observed when replacing a PJ Control Unit with the CC-PJ-0707?

A

Please note that there is no external dimming function (not possible to perform external control using the D-Sub 15 pin).
ON/OFF control is performed using a photo coupler specification and it is driven using DC 24V.
The input method used is DC 24V.
It is limited to a single channel.

QA No. 11-0127

Q Is it possible to perform external dimming for the CC-PJ-0707?

A

There is no external dimming control function.

QA11-0126